翻訳と辞書
Words near each other
・ Fast Lane Ventures
・ Fast Lanes and Country Roads
・ Fast Last!
・ Fast Library for Number Theory
・ Fast Life
・ Fast Life (David Murray album)
・ Fast Life (film)
・ Fast Life (Hadise album)
・ Fast Life (Hadise song)
・ Fast Life (Kool G Rap song)
・ Fast Life (Paul Wall album)
・ Fast Life (Young Noble & Deuce Deuce album)
・ Fast Life Yungstaz
・ Fast loader
・ Fast Local Internet Protocol
Fast low angle shot magnetic resonance imaging
・ Fast Low-Ionization Emission Region
・ Fast Machine
・ Fast Mail
・ Fast Mail (Amtrak train)
・ Fast Mail (Milwaukee Road)
・ Fast Mail (Southern Railway)
・ Fast man
・ Fast Man Raider Man
・ Fast mapping
・ Fast marching method
・ FAST marketing
・ Fast Masters
・ Fast men
・ Fast Mimicking Diet


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Fast low angle shot magnetic resonance imaging : ウィキペディア英語版
Fast low angle shot magnetic resonance imaging
Fast low angle shot magnetic resonance imaging (FLASH MRI)〔〔 is a basic measuring principle for rapid MRI invented in 1985 by Jens Frahm, Axel Haase, W Hänicke, KD Merboldt, and D Matthaei (German Patent Application P 35 04 734.8, February 12, 1985) at the (Max-Planck-Institut für biophysikalische Chemie ) in Göttingen, Germany. The technique is revolutionary in shortening MRI measuring times by up to two orders of magnitude.
Different manufacturers of MRI equipment use different names for this experiment. Siemens uses the name FLASH, General Electric used the name SPGR (Spoiled Gradient Echo), and Philips uses the name CE-FFE-T1 (Contrast-Enhanced Fast Field Echo) or T1-FFE. Depending on the desired contrast, the generic FLASH technique provides spoiled versions that destroy transverse coherences and yield T1 contrast as well as refocused versions (constant phase per repetition) and fully balanced versions (zero phase per repetition) that incorporate transverse coherences into the steady-state signal and offer T1/T2 contrast.
The introduction of FLASH MRI sequences in diagnostic imaging for the first time allowed for a drastic shortening of the measuring times without a substantial loss in image quality. In addition, the measuring principle led to a broad range of completely new imaging modalities. For example,
*cross-sectional images with acquisition times of a few seconds enable MRI studies of the thorax and abdomen within a single breathhold,
*dynamic acquisitions synchronized to the electrocardiogram generate movies of the beating heart,
*sequential acquisitions〔〔 monitor physiological processes such as the differential uptake of contrast media into body tissues,
*three-dimensional acquisitions〔 visualize complex anatomic structures (brain, joints) at unprecedented high spatial resolution in all three dimensions and along arbitrary view directions, and
*magnetic resonance angiography (MRA) yields three-dimensional representations of the vasculature.
In 2010, an extended FLASH method with highly undersampled radial data encoding and iterative image reconstruction achieved real-time MRI with a temporal resolution of 20 milliseconds (1/50th of a second).〔〔 Taken together, this latest development corresponds to an acceleration by a factor of 10,000 compared to the MRI situation before 1985. In general, FLASH denoted a breakthrough in clinical MRI that stimulated further technical as well as scientific developments up to date.
==Physical Basis==
The physical basis of MRI is the spatial encoding of the nuclear magnetic resonance (NMR) signal obtainable from water protons (i.e. hydrogen nuclei) in biologic tissue. In terms of MRI, signals with different spatial encodings that are required for the reconstruction of a full image need to be acquired by generating multiple signals - usually in a repetitive way using multiple radio-frequency excitations.
The generic FLASH technique emerges as a gradient echo sequence which combines a low-flip angle radio-frequency excitation of the NMR signal (recorded as a spatially encoded gradient echo) with a rapid repetition of the basic sequence. The repetition time is usually much shorter than the typical T1 relaxation time of the protons in biologic tissue. Only the combination of (i) a low-flip angle excitation which leaves unused longitudinal magnetization for an immediate next excitation with (ii) the acquisition of a gradient echo which does not need a further radio-frequency pulse that would affect the residual longitudinal magnetization, allows for the rapid repetition of the basic sequence interval and the resulting speed of the entire image acquisition.〔〔 In fact, the FLASH sequence eliminated all waiting periods previously included to accommodate effects from T1 saturation. FLASH reduced the typical sequence interval to what is minimally required for imaging: a slice-selective radio-frequency pulse and gradient, a phase-encoding gradient, and a (reversed) frequency-encoding gradient generating the echo for data acquisition.
For radial data sampling, the phase- and frequency-encoding gradients are replaced by two simultaneously applied frequency-encoding gradients that rotate the Fourier lines in data space.〔〔 In either case, repetition times are as short as 2 to 10 milliseconds, so that the use of 64 to 256 repetitions results in image acquisition times of about 0.1 to 2.5 seconds for a two-dimensional image. Most recently, highly undersampled radial FLASH MRI acquisitions have been combined with an iterative image reconstruction by regularized nonlinear inversion to achieve real-time MRI at a temporal resolution of 20 to 30 milliseconds for images with a spatial resolution of 1.5 to 2.0 millimeters.〔 This method allows for a visualization of the beating heart in real time - without synchronization to the electrocardiogram and during free breathing.〔

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Fast low angle shot magnetic resonance imaging」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.